Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation

Product Details
After-sales Service: Yes
Warranty: 1 Year
Feature: Environmental, Fireproof, Light Weight, Metal Panel
Still deciding? Get samples of US$ 1000/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
3000000 RMB
Type of Ownership
Limited Company
  • Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation
  • Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation
  • Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation
  • Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation
  • Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation
  • Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation
Find Similar Products
  • Overview
  • Product Description
  • Main Characteristics
  • Product Parameters
  • Detailed Photos
  • After Sales Service
  • Packaging & Shipping
  • Projects fotos
Overview

Basic Info.

Model NO.
WSLK-JJSSB-003
Material
Stainless Steel SUS304/201/Coated Steed
Applicable Industries
Building Material Shops, Manufacturing Plant, Foo
Type
Vertical Flow Clean Bench
Color
Gray, White
Inside Diameter
Inside Diameter
Usage
Research Institute, Hospital, School, Company
Filter Efficiency
99.995%@0.3um
Inside Size
880*650*580mm
Outside Size
1040*690*1600mm
Transport Package
Standard Seaworth Package
Specification
1040*690*1600mm
Trademark
WISE LINK
Origin
China
HS Code
841460909
Production Capacity
500 Pices / Month

Product Description

Product Description

 
Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation
Laminar airflow hood is a kind of air purification equipment that can provide partial high cleanliness.It uses a fan and a high-efficiency filter to purify the dust particles in the airflow,and evenly transports the clean airflow to the coverage area of the laminar flow hood after passing through the air flow equalizing mesh,thereby improving the cleanliness of the area and protecting the area.The production,operating environment and material safety of the area are protected.

 

Main Characteristics

Features of the product:
1. The fan has a long lifespan, produces less vibration, and is automatically set to a consistent speed.
2. Excellent air distribution performance with no leakage danger thanks to a double-layer negative pressure structure.
3. The design of the tank guarantees cleanliness, uniformity both inside and outside, and tightness without any dead corners.
4. A separate control box can be used or the control panel can be mounted on the box.

 

Item  WSLK -1200  WSLK -1500  WSLK -2000
Dimensions mm (W*D*H) 1200*600*600 1500*1000*600 2000*1000*600
Rated air volume  (m³/ h) 800~1200 2200~2600 3000~3500
Fan power 300W 600W 1000W
Wind speed (m/s) 0.45 ±20%
Cleanliness level  A
Noise <65 dB
Luminance (LUX) ≥300
Control methods Inverter control / LCD screen control
Power supply / Voltage AC 220V / 50HZ

Product Parameters

Structure  diagram:
1.PAO testing port
2.Differential pressure gauge
3.Controller
4.LED lamp
5.Clamping  components      
6.Gel Seal HEPA
7.Air flow equalizing mesh    
8.Air blower 9.Hand ring
Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation
 

Detailed Photos

Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation
Horizontal Laminar Flow Hood Diagram

Similarly, the airflow direction in the enclosed mechanism gives these laminar flow hoods their name. In theory, the flow originates from above, like the vertical laminar hoods, but it soon changes and travels across the functional surface from back to front. There are instances where the air intake is done from the side. Both approaches use the horizontal flow principle to protect the product and material.

Vertical Laminar Flow Hood Diagram

The vertical laminar flow is directed by a vertical laminar flow system into a descending filter above the operating surface, which is situated atop the working chamber. In order to remove the particles, it shifts the flow via the front access region and highlights the effect of gravity. There are situations when the mass of emerging contaminants (ECs) or micro-pollutants is insufficient. The airflow helps to remove the great majority of the particles from the box, and some of them land on the surfaces of the enclosure that are readily cleaned.
A vertical laminar flow hood is designed similarly to a cleanroom, with the filtering element located on the upper side. The key advantage is that it doesn't require a lot of floor space, which is crucial for some labs.


 
Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation
 

 

After Sales Service

Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation

Packaging & Shipping

Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation
Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation

Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation
Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation

Projects fotos

Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation
Custom Cleanroom Laminar Flow Hood for Lab Airflow Workstation

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier