Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System

Product Details
After-sales Service: Yes
Warranty: 1 Year
Feature: Environmental, Fireproof, Light Weight, Metal Panel
Still deciding? Get samples of US$ 12/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
3000000 RMB
Type of Ownership
Limited Company
  • Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System
  • Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System
  • Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System
  • Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System
  • Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System
  • Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • The different′s cores
  • Clean room Door
  • Installation Instructions
  • Our Advantages
  • Projects fotos
  • FAQ
Overview

Basic Info.

Model NO.
WSLK-CLP-800
Certification
CCC, ISO9001
Customized
Customized
Top Steel Thickness
0.35mm/0.4mm/0.5mm/0.6mm/0.7mm/0.8mm
Back Steel Thickness
0.35mm/0.4mm/0.5mm/0.6mm/0.7mm/0.8mm
Application
Cold Room/Envelope/Wall/Roof/Ceiling
Surface Type
Lowribbed/Orange Peel/Flat/Ribs
Paint
PE/PVDF/SMP/HDP
Insulated
Yes
Color
White/Blue/Gray/Red or Cutomized
Transport Package
Standard Seaworth Package
Specification
950mm-1150mm
Trademark
WISE LINK
Origin
China
HS Code
7326901900
Production Capacity
500000m/Day

Product Description

Product Description

The development of clean rooms is closely linked to modern industry and cutting-edge technology. Due to the environmental requirements of the precision machinery industry (such as gyroscopes, miniature bearings, etc.), the semiconductor industry (such as the production of large-scale integrated circuits), etc., the development of clean room technology has been promoted.

A clean room is a space that can be used for human activities when the air cleanliness reaches a specified level. Its function is to control the contamination of particulates (dust particles). To meet the production of precision products and scientific experiment activities. The clean room is by no means limited to "clean", different industries and departments have considerable requirements for temperature, temperature, lighting, noise, static electricity, micro-vibration multi-functional comprehensive whole, is a set of building decoration (closed decoration with the atmosphere relatively isolated), purification of air conditioning, pure water, pure gas, power electricity, lighting electricity, process pipeline and other professional and technical products.


Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System

Product Parameters

Width 980mm
Max Length 7500mm
Wall TCK 50mm
Steel Thickness 0.4-0.8mm
Outer plate material PPGI,Al-mg-Mn Alloy steel,SS steel,Ti-Zn steel,HPL,VCM
Coating PE,PVDF,HDP
Core material PU,rock wool,magnesium board,paper honeycomb,aluminium honeycomb,plaster,EPS, etc.
Frame Thickness 0.6-0.8mm
Application Pharmaceutical Clean Room, Electronic Clean Room, Food Clean Room, etc.
 
 
Wall Panel
Thickness - 50mm, double color painted hot-dipping galvanized steel sheet, 0.5mm thick PE coated steel sheet, 0,8mm thick GI
frame, infill with rock wool, comply with accessories below in item Height: 2600mm.
Wall Panel accessories
Aluminum joint profiles
Top track (aluminum slot), 30*50*30mm
Adjustable floor track
Straight corners
R50 round corner inside
3-way connector inside (per pc)
middle type 3-way connector outside
door seal (per pair)
Ceiling panels
Thickness - 50mm, double layer color painted hot-dipping galvanized steel sheet, 0.5mm thick PE coated steel sheet, 0.8mm thick GI
frame, infill with rock wool, with single glass magnesium oxide boards for reinforcement.
Ceiling Panel accessories
Aluminum joint profiles
Aluminum Grid
Hanging bar, with expansion bolts, T screw, square regulator, connector, nuts
Clean room Doors
Steel doors: 50mm thickness; 1.0 mm double-side electro galvanized steel sheet, with paper honeycomb inside; Including 50mm thick
door leaf, 50mm thick steel frame, hinge, GEZE lock, Auto-down bottom seal, with double 5mm tempered glass window (round or
rectangular window), not include door closer.
Single leaf, size 1000*2100mm
Double leaf, size 1900*2100mm
Door Closer, Brand: GEZE 1000C
Interlock
Electronic interlock to control two or more doors, with electromagnetic lock, light Indicator and main control box
2 Doors
Windows
Double tempered glass view window, joints filled with silicon sealant, with vapor absorption, 5mm thick glass
Size: 1200*1000*50mm
Size: 1500*1000*50mm
Silicone
Dow corning silicone
PVC conduits
PVC conduit (25mm) inside wall panels
Opening cost
Openings in ceiling/wall panels
 
Effective width Wall panel: 950mm 1150mm
Ceiling panel: 950mm
Length According to customer's request(less than 7500mm)
Core Materials PU/Rock Wool/Glass Magnesium
Structure Upper and lower layer: Color steel sheet
Middle: PU/Rock Wool/Glass Magnesium
Thickness Color steel sheet: 0.3-0.8mm
Rock wool: 50mm 75mm 100mm
The Density of Rock Wool 40kg/m3 -120kg/m3
Color RAL Standard
Character Fireproof, heat insulation, sound proof, green and environmental friendly
Use pharmaceutical & electronic clean rooms, hospital operating rooms, food processing factories, offices, etc.

The different's cores

 

Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System
Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System
Clean room Introduction:
Cleanrooms are essential to any manufacturing process where particulate contamination can affect the quality of goods produced.
Specific clean room classifications and ISO class code descriptions provide protective guidelines and secure environments
through controlled air filtration, which lowers the possibility of product contamination or large particulate interference within
critical process manufacturing. Specific cleanroom requirements and ISO 14644-1 cleanroom standards are used to protect
consumers from any potential flaw or mishandling of a product.

 
Clean rank of suspended particles in air of clean room or clean area
ISO rank for air cleanness
Bigger or equal to maximum concentration limits in table (P/m3-air)
0.1um
0.2um
0.3um
0.5um
1um
5um
American federal 209E rank for cleanness
ISOClass1
 
 
 
 
 
 
 
ISOClass2
100
24
10
4
 
 
 
ISOClass3
1000
237
102
35
8
 
1
ISOClass4
10000
2370
1020
352
83
 
10
ISOClass5
100000
23700
10200
3520
832
29
100
ISOClass6
1000000
237000
102000
35200
8320
293
1000
ISOClass7
 
 
 
352000
83200
2930
10000
ISOClass8
 
 
 
3520000
832000
29300
100000
ISOClass9
 
 
 
35200000
8320000
293000
300000

Clean room Door

Cleanroom door is used in all levels of cleanrooms, purified rooms, dust free rooms, sterile rooms, movable rooms and places where sandwich panels are used as partitions. The surroundings are double-sealed, heat-preserving and heat-insulating. Sandwich panels or stainless steel panels can be used to customize cleanroom doors of different specifications; the door locks, colors, sweeping strips can be configured as required.
Classification: Swing Door (Single Door, Double Door, unique Door, Glass Door), Electric  Sliding Door, Fast Rolling Door
Classified by different materials: sandwich panel door, steel door, melamine resin door, stainless steel door
The door and the wall panel are connected evenly on both sides, all corners use arc transitions, sanitary lifting hinges, push-type door locks, and automatic sealing strips.
Door lock and hinge: The structure and design can achieve a smooth connection on both sides, and the door lock system should avoid hand contact pollution.
Automatic lifting sealing strip at the bottom of the door: three sides of the door frame should use sealing tape and automatic lifting sealing strip at the bottom of the door to ensure the air tightness of the door system.
Electronic interconnection lock classification: electric plug interconnection lock, electromagnetic interconnection lock, cathode interconnection lock
Clean door thickness 50 mm, face panel can be stainless steel plate, color coating, cold plate baking paint.


Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System

Installation Instructions

 

Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System
Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System
 

Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System

Our Advantages

Advantage:

  1. Core material fire ratings can be viewed.
  2. The cleanroom wall panel system is connected by aluminum profiles, modular installation, convenient and fast, non-standard can be customized.
  3. Factory customization.
  4. Diversified core material for different environments, fire protection, thermal insulation, noise reduction, moisture resistance.
  5. The factory provides customers with 6 different kinds of steel and more services.
  6. The cleanroom wall panel, strength, flatness, and aesthetics of the panel are greatly improved, and the product quality is more stable.
  7. The hole reinforcement reservation and the line pipeline box are pre-assembled into the interior of the board in the factory, effectively reducing the secondary pollution during use, especially in the operating room.
Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom SystemModular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System

Projects fotos

Modular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom SystemModular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom SystemModular Operating Theater with Laminar Flow HEPA for Hospital Cleanroom System

FAQ

1.Are you a Factory/Manufacturer or Trading Company?
We are a manufacturer with 15 years experience of production and have a modern standard plant of 100000 m².

2.How about your lead time?
It will take 3-7 days for budget and design according to the drawings after receiving the deposit.  15-30 days if there are some special sizes.

3.How about your core competitiveness?
We have the first automatic production line in the world. Compared with the traditional manual production line, the production efficiency increased by 6-8 times, leading most competitors. That means lower cost and higher quality.

4.Do you have your own construction team?
No, but all of our cleanroom panels and connected parts are easy for disassemble and installation due to our excellent design. What's more, we provided the instruction and videos for installation and we can send our professional superviors to the site.

5.How many kinds products do you have?
At present, we have more than 30 different products, including clean room wall panel system, ceiling system, clean room door, clean room window and so on.

6.Can you provide samples? Is it free or extra?
Yes, we can provide samples for free, but we would appreciate it if freight to collect.

7.What is your terms of payment ?
30% T/T prepay, 70% T/T before delivery. We can discuss payment if we have more cooperation in the future.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier